DANGER
IMPORTANT SAFETY PREAUTIONS
●
Read and understand this safety information before
operating or servicing this Navien Water Heater.
●
Confirm the location of the gas shut-off valve. Close the
manual shut-off valve if the Navien Water Heater ever
becomes subjected to overheating, fire, flood, physical
damage or any other such damaging condition during
servicing.
●
DO NOT turn on the water heater unless water and gas
supplies are fully opened.
●
DO NOT turn on the water heater if the cold water supply
shut-off valve is closed.
●
Make certain power to the water heater is “OFF” before
removing the front cover for any reason.
●
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
●
Improper adjustment, alteration, service or maintenance
can cause property damage, personal injury, or death.
●
To prevent scalding, always check the temperature of the
hot water after servicing.
●
DO NOT attempt to change the water temperature while
someone is using the water heater.
●
DO NOT use parts other than those specified for this
equipment.
●
DO NOT operate the water heater if you feel something is
wrong with the unit.
●
DO NOT allow children to operate or otherwise handle the
unit.
DANGER
INSTALLATION REQUIREMENTS
●
Installation conditions may affect how the water heater is
serviced. Read all related information in the “Installation
Manual”.
●
The Water Heaters must be installed according to all local
and state codes or, in the absence of local and state codes,
the most recent edition of the “National Fuel Gas Code
(ANSI Z223.1/NFPA 54)” in the USA or the “National Gas and
Propane Installation Code (CAN/CSA B 149.1)” in Canada.
●
Massachusetts code requires this water heater to be installed
in accordance with Massachusetts Plumbing and Fuel Gas
Code 248 CMR Section 2.00 and 5.00.
DANGER
HOT
BURN
HOT WATER TEMPERATURE SETTING
●
Water temperatures at or above 125°F (52°C) can cause
severe burns instantly or death from scalds.
●
Households with small children, disabled, or elderly persons
may require 120°F (49°C) or lower temperature setting to
prevent contact with “HOT” water.
●
To prevent scalding, check water temperature after servicing.
●
If the proposed water heater outlet temperature is at or
above 125°F (52°C), a thermostatically controlled mixing
valve or temperature limiting valve should be considered to
reduce the risk of scalding. Contact a licensed plumber or
the local plumbing authority for further information.
●
This Navien Water Heater is factory set at 120°F (49°C) for
your safety and comfort. Increasing the set temperature
increases the risk of accidental scalding. Consult the chart
below before you decide to adjust the set temperature.
Water Temperature Time in which a young child can suffer
a full thickness (3rd degree) burn
70 °C (160°F)
Less than 1 second
60 °C (140°F)
1 second
55 °C (130°F)
10 second
49 °C (120°F)
10 minutes
37 °C (110°F)
very low scald risk
Содержание NPE-180A
Страница 3: ......
Страница 57: ...Version 2 21 56 NPE Service Manual 4 10 Electrical Diagnostic Points ...
Страница 86: ...Troubleshooting 85 ...
Страница 156: ...Installation the Outdoor Vent Cover 155 9 5 Ventilation Flow Intake Air Flow Exhaust Gas Flow ...