Version 2.21
74 NPE Service Manual
Error Code Sub
Code
Function
Self-diagnostic/Action
E407
1
Abnormal Hot water outlet thermistor (Open)
●
Check the thermistor.
●
Replace the thermistor.
2
Abnormal Hot water outlet thermistor (Short)
E421
1
Abnormal Cold water inlet thermistor (Open)
●
Check the thermistor.
●
Verify [C] value in DIAGNOSTIC mode.
●
Replace the thermistor.
2
Abnormal Cold water inlet thermistor (Short)
E432
1
Abnormal Cold water inlet2: thermistor (Open)
●
Check the thermistor.
●
Check thermistor voltage and resistance values.
●
Replace the thermistor.
2
Abnormal Cold water inlet2: thermistor (Short)
E434
1
Abnormal water adjustment valve. (Open)
●
Check the water adjustment valve.
2
Abnormal water adjustment valve. (Close)
E438
0
Abnormal circulation pump. ("A" models only)
●
Check the circulation pump.
●
Check water filter for blockage.
●
Check the flow sensor.
●
Check the cold water main line.
●
Set to Internal Recirculation mode and verify flow rate.
E439
0
Abnormal flow sensor
●
Check the flow sensor.
E441
1
Abnormal Hot water inlet2: thermistor(Open)
●
Check the thermistor.
2
Abnormal Hot water inlet2: thermistor(Short)
●
Replace the thermistor.
E445
1
Abnormal mixing valve(Open)
●
Check the mixing valve.
2
Abnormal mixing valve(Close)
E515
1~7
Abnormal communicatin between PCB and Ignitor.
●
Check the PCB.
8
Abnormal communication between PCB and
Ignitor
●
Check the PCB connection.
●
Check the Ignitor.
9
Abnormal communication between PCB and FAN
●
Check the PCB connection.
●
Check the Fan.
10
Abnormal monitoring device of PCB
●
Check the PCB connection.
●
Check the Dual Venturi.
11~12
Abnormal communication between PCB and Dual
Venturi
●
Check the PCB connection.
●
Check the Dual Venturi.
E517
0
Abnormal dip switch setting
●
Check the dip switches on the front panel and PCB.
E593
1
Abnormal panel key
●
Check the Panel.
E594
0
Abnormal input data from High limit switch of Heat
exchanger
●
Check the PCB.
1
Abnormal input data from exhaust sensor
●
Check the exhaust sensor wiring connection.
●
Check the exhaust sensor.
2
Abnormal input data from flame rod
●
Check the flame rod wiring connection.
●
Check the flame rod.
3~14
Abnormal memory of PCB
●
Check the PCB
15
Below the range of input data from Pressure sensor
●
Check the Pressure sensor wiring connection.
●
Check the output voltage of pressure sensor.
16
Over the range of input data from Pressure sensor