Troubleshooting 93
5.1.6 046Error
Error occurrence conditions and check items
Replace heat exchanger
thermistor.
Check connector
( #1 and #2 of CON 6)
1 step: Flushing, Clean Filter
2 step: Try to restart
3 step: Replace PCB
Yes
Yes
Is heat exchanger
thermistor normally
operating?
Is resistance
within normal range?
(refer to page 59)
NO
NO
5.1.7 047Error
Error occurrence conditions and check items
Check connector
(#9 and #10 of CON6)
Replace exhaust thermistor
Resistance between #9 and #10 of CON6 is from 2kΩ
to 300kΩ at normal condition. (see page 52 for
Wiring Diagram)
NO
Is exhaust thermistor
operating normally?
Yes