Testing method
Error
Cause
Testing method
Ignition
failure
Gas supply fault
1.
Check that the main gas valve is open.
2.
Check the gas supply pressure.
NG: 17 - 25 mbar, LP: 25 – 35 mbar
LP pressure drops can occur during winter.
3.
Check the diameter of the flexible pipe to ensure it is compatible with the boiler.
4.
If a CSST connector is used, ensure that it has not been overtightened. An
overtight connection can deform the seal and obstruct the flow of gas.
5.
Check the class of pressure meter.
Electrode gap and shape
faults
Insufficient electrode gap and deformed electrodes can prevent ignition.
Recommended gap: approx. 3-4 mm (1/8"). Replace electrode if defective.
Ignition can fail due to improper gap even if the discharge appears normal
in the flame monitoring window. Disassemble to gain access to the
electrode and inspect the gap.
Содержание NCB-24LSWE
Страница 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Страница 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Страница 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Страница 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Страница 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Страница 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Страница 140: ...138 NCB Service Manual Version 1 0 Memo...
Страница 141: ...NCB Service Manual 139 Version 1 0 Memo...
Страница 142: ...140 NCB Service Manual Version 1 0 Memo...
Страница 143: ...NCB Service Manual 141 Version 1 0 Memo...
Страница 144: ...142 NCB Service Manual Version 1 0 Memo...