NCB Service Manual 71
Version 1.0
4.9.12
Secondary Heat Exchanger
Item
Description
Function
1.
Secondary component used in the boiler for heat transfer.
2.
There are multiple paths of water pipes on the heat exchanger as well as inside the
combustion chamber which minimises heat loss.
Fault
1.
Water and/or exhaust gas leaks.
2.
Scale deposits in the heat exchanger can cause water in the boiler to bubble.
Symptoms
1.
Exhaust gas leaks.
2.
Overheating of water causes bubbling noises.
Error codes
E016, E030, E047
Diagnostics
1.
Visual inspection: Check for surface cracks on the heat exchanger.
2.
Audible inspection: Listen for bubbling noises from inside the boiler.