60 NCB Service Manual
Version 1.0
4.9
Key Component Descriptions
4.9.1
PCB
Item
Description
Function
Controls each component and monitors the overall performance of the unit.
Fault
PCB malfunction.
Symptoms
A system component may not operate and generate an error code. In most PCB failures, the boiler
will not operate until the fault is resolved.
Error codes
E515, E615
Diagnostics
Visual inspection: Check wire connections are secure and inspect for wire damage, and/or PCB
heat damage.
Testing/inspection
information