18 NCB Service Manual
Version 1.0
Specification
Unit
NCB-
24LSWE
NCB-
28LSWE
NCB-
34LSWE
NCB-
40LSWE
Specific flow for kitchens (ΔT=45°C)
l/min
7.6 8.9 10.8
12.7
Electrical supply
-
230 V / 50 Hz
Nominal current
A 0.6
0.62
Electrical maximum rating
W 130
Electrical protection
- IP
X5D
Boiler mounting method
- Wall-mounted
Flue exhaust/Air intake system types
- B23-B33-B53-C13-C33-C43-C53-C63-C83
Flue exhaust/Air intake system diameters
mm
Coaxial Ø60/100 and Ø80/125–Dual duct Ø80/80
Max. horizontal coaxial pipe length Ø60/100
m
20
Max. vertical coaxial pipe length Ø60/100
m
21
Equivalent elbow length at 90° Ø60/100
m
1.3
Equivalent elbow length at 45° Ø60/100
m
1
Max. horizontal coaxial pipe length Ø80/125
m
68
Max. vertical coaxial pipe length Ø80/125
m
70
Equivalent elbow length at 90° Ø80/125
m
2.2
Equivalent elbow length at 45° Ø80/125
m
1
Equivalent length of adapter Ø60/100 => Ø80/125
m
0.5
Max. dual duct length Ø80-Ø80
m
110
Equivalent elbow length at 90° Ø80
m
2.2
Equivalent elbow length at 45° Ø80
m
1.4
Hydraulic connection diameter
Heating mm
22
DHW mm
15
Gas inlet
mm
22
Dimensions (width x depth x height)
mm
440 x 350 x 695
440 x 380 x 695
Weight
kg 38
42
Содержание NCB-24LSWE
Страница 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Страница 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Страница 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Страница 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Страница 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Страница 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Страница 140: ...138 NCB Service Manual Version 1 0 Memo...
Страница 141: ...NCB Service Manual 139 Version 1 0 Memo...
Страница 142: ...140 NCB Service Manual Version 1 0 Memo...
Страница 143: ...NCB Service Manual 141 Version 1 0 Memo...
Страница 144: ...142 NCB Service Manual Version 1 0 Memo...