124 NCB Service Manual
Version 1.0
Figure 4
6.
Disconnect the wiring connector from the fan
assembly, and then remove the 2 screws from the
gas valve connection as shown in figure 5 below.
Figure 5
7.
Pull out the fan assembly and remove the 2 screws
that secure the air intake port to the fan assembly.
8.
Remove the four screws from the bottom of the fan
assembly.
Figure 6
9.
Detach the fan motor from the assembly and replace
it with the new part.
10.
Replace the 3 screws used to attach the fan motor to
the assembly.
11.
Reinstall the fan assembly to the bracket by using the
mounting screw.
12.
Attach the gas valve connection back to the fan
assembly by using the 3 screws as shown in figure 6.
13.
Reconnect the wiring connector from the fan
assembly.
14.
Turn on water supply, power supply, and gas supply
to the unit.
NOTE
Do not over-tighten the screws for
the fan motor replacement with high
torque drill. This may cause damage
to the part(s).
6.2.4
Flame Rod
1.
Turn off the gas supply to the unit.
2.
Disconnect the unit from the power supply.
3.
Turn off the water supply to the unit.
4.
Remove the Ignition Transformer insulated cables.
5.
Remove the 2 screws from the flame rod as shown in
figure 7 below.
Figure 7
Содержание NCB-24LSWE
Страница 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Страница 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Страница 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Страница 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Страница 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Страница 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Страница 140: ...138 NCB Service Manual Version 1 0 Memo...
Страница 141: ...NCB Service Manual 139 Version 1 0 Memo...
Страница 142: ...140 NCB Service Manual Version 1 0 Memo...
Страница 143: ...NCB Service Manual 141 Version 1 0 Memo...
Страница 144: ...142 NCB Service Manual Version 1 0 Memo...