52 NCB Service Manual
Version 1.0
Item
Description
Display
(W)
Maintenance
time
This menu sets the maintenance time.
Range
Default
0 to 999 days 0
Maintenance time
(+) Reset all
parameters
This menu resets all boiler parameters to the default settings. To
reset:
1. Press [+] or [–] to change the display to “YES”.
2. Press [ECO].
When “No” appears on the display, all parameters have been reset.
In <Parameter initializing
mode>,
press [+] or [-]
or
(*) Change
password
This menu sets a new password for <Parameter setting mode>.
To set a new password:
1. Move to [*.PSC] and press [ECO]. The current password is displayed
and the first digit flashes.
2. Press [+] or [–] to change the value.
3. Press [Summer/Winter] to change position.
4. When the new password is entered, press [ECO] to save it. The new
password is displayed on the front panel for three seconds and
then the boiler returns to <Parameter setting mode>.
NOTE
If you do not press [ECO] for 10 sec after
entering the new password, the new
password is automatically saved and
[*.PSC] is displayed on the front panel.
In <Password setting
mode>, the password is
displayed. The password
characters flash at 500
msec intervals when they
can be changed.
Содержание NCB-24LSWE
Страница 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Страница 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Страница 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Страница 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Страница 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Страница 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Страница 140: ...138 NCB Service Manual Version 1 0 Memo...
Страница 141: ...NCB Service Manual 139 Version 1 0 Memo...
Страница 142: ...140 NCB Service Manual Version 1 0 Memo...
Страница 143: ...NCB Service Manual 141 Version 1 0 Memo...
Страница 144: ...142 NCB Service Manual Version 1 0 Memo...