NCB Service Manual 75
Version 1.0
4.9.16
Water Pressure Sensor
Item
Description
Function
Analysis of heating system water pressure ratios.
Fault
Unable to detect or measure changes of water pressure.
Symptoms
The water top-up system does not operate automatically.
Error codes
E351, E352, E353
Diagnostics
1.
Visual inspection: Check the circulation pump’s wiring connections.
2.
Voltage test: Test the voltage meets the specifications shown below.
Testing/inspection
information
Black-Red: DC 0 -5 V