NCB Service Manual 111
Version 1.0
5.2.17
Error 407
Error conditions and checklist
Error
Description
E407
Hot water outlet
thermistor open or
short
If an error (open: -10°C or lower) in the DHW Outlet Elbow input temperature sensor is detected, the
system displays the 407E error on the front panel.
Check items
1.
Check if the hot water temperature sensor connector is wet due to any reason and if the
connector is connected properly.
2.
Check if the temperature sensor is open or short