TIMx_CCEN.CCxNEN=1.
Figure 11-25 Complementary output with dead-time insertion
User can set TIMx_BKDT.DTGN to programme the dead-time delay for each of the channels.
Redirecting OCxREF to OCx or OCxN
User can set TIMx_CCEN.CCxEN and TIMx_CCEN.CCxNEN to re-directed OCxREF to the OCx output or to
OCxN output, in output mode.
Here are two ways to use this function. When the complementary remains at its inactive level, user can use this
function to send a specific waveform, such as PWM or static active level. User can also use this function to set both
outputs in their inactive level or both outputs active and complementary with dead-time.
If user set TIMx_CCEN.CCxEN=0 and TIMx_CCEN.CCxNEN=1, it will not complemented, and OCxN will
become active when OCxREF is high. On the other hand, if user set TIMx_CCEN.CCxEN=1 and
TIMx_CCEN.CCxNEN=1, OCx will become active when OCxREF is high. On the contrary, OCxN will become
active when OCxREF is low.
Complementary output
with dead-time insertion
`
Dead-time waveform
with delay greater
than the negative
pulse
Dead-time waveform
with delay larger
than the positive
pulse
OCxREF
OCx
OCxN
Delay
OCxREF
OCx
OCxN
Delay
OCxREF
OCx
OCxN
Delay
Delay