If the injection discontinuous mode is used on ADC1 and ADC2 at the same time, when the first trigger is generated,
the first group of injection channels of ADC1 is converted; when the second trigger is generated, the first group of
injection channels of ADC2 is converted; when the third trigger is generated, the second group of injection channels
of ADC1 is converted. When the fourth trigger is generated, the second group of injection channels of ADC2 is
converted, and the cycle is continues. If ADC1 or ADC2 sets ADC_CTRL1.JENDCIEN, a JENDC interrupt will be
generated when the conversion of the injection sequence of ADC1 or ADC2 is completed. When all injection
sequences have been converted, another external trigger is generated, and the rotation trigger starts again.
Figure 9-14 Rotation trigger: inject channel group in discontinuous mode
9.9.7
Mixed synchronous regular mode + synchronous injection mode
In this mode, the transition of the synchronous injection channel can interrupt the transition of the synchronous
regular channel.
Note: In this mode, the sequence of synchronous conversion of ADC1 and ADC2 needs to be set to the same time, or
the interval of the trigger signal is greater than that of the sequence with longer conversion time. If the interval
between the trigger signals is smaller than the conversion of the longer sequence, the shorter sequence may start to
convert again when the longer sequence is not completed.
9.9.8
Mixed synchronous regular mode + rotation trigger mode
Rotation triggered transitions of the injection channel can interrupt transitions of a synchronous regular channel.
When the injection channel event occurs, the injection rotation conversion starts immediately. If a regular conversion
is in progress, both the master ADC and the slave ADC will stop the regular conversion to ensure that the regular
conversion can be resumed synchronously after the injection conversion is completed.
Note: In this mode, the sequence of synchronous conversion of ADC1 and ADC2 needs to be set to the same time, or
the interval of the trigger signal is greater than that of the sequence with longer conversion time. If the interval
ADC1
ADC2
Conversion
Sampling
Trigger
JENDC(ADC2)
JENDC(ADC1)
CH5
CH1
CH6
CH2
CH7
CH3
CH8
CH4