814
/
838
Nations Technologies Inc.
Tel
:
+86-755-86309900
:
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
Bit field
Name
Description
TIM1_CC6 automatically switches between OPAMP1 and OPAMP2, and TIM8_CC6
automatically switches between OPAMP3 and OPAMP4.
0: Disable automatic switching;
1: Enable automatic switching.
15
RANGE
OPAMP voltage range (OPAMP Operational amplifier power supply range).
0: Low voltage range (VDDA < 2.4V);
1: High voltage range.
14
CALOUT
OPAMP calibration output (Operation amplifier calibration output)
When this signal toggles, the offset during calibration mode is calibrated.
13
TSTREF
Retained, the reset value must be maintained.
12
Reserved
Retained, the reset value must be maintained.
11
CALON
Calibration mode enabled
0: Normal mode;
1: Calibration mode.
10:8
VPSEL[2:0]
OPAMP non inverted input selection
VPSEL[2:0
OPAMP1
OPAMP2
OPAMP3
OPAMP4
000
PA1
PA7
PC9
PC3
001
PA3
PB0
PA1
DAC1/PA4
010
DAC2/PA5
PE8
DAC2/PA5
PC5
011
PA7
Reserved
PC3
Reserved
100
Reserved
Reserved
Reserved
Reserved
others
Reserved
Reserved
Reserved
Reserved
Note: DAC2 is directly connected to PA5
7:6
VMSEL[1:0]
OPAMP inverted input selection
VMSEL[1:0]
OPAMP1
OPAMP2
OPAMP3
OPAMP4
00
PA3
PA2
PC4
PB10
01
PA2
PA5
PB10
PC9
10
Reserved
Reserved
Reserved
PD8
11
Floating
Floating
Floating
Floating
Note: VM is floating (for internal PGA (No Filter) mode, follow mode)
5:3
PGAGAN[2:0]
OPAMP gain setting (Operational amplifier Programmable amplifier gain value)
000: Internal PGA gain 2;
001: Internal PGA gain 4;
010: Internal PGA gain 8;
011: Internal PGA gain 16;
100: Internal PGA gain 32;
Others: Internal PGA gain 2.
2:1
MOD[1:0]
OPAMP mode selection (Operational amplifier PGA mode)
0x: External zoom mode;
10: Internal PGA enable;
11: Internal follow mode.