Bit field
Name
Description
1: HSYNC error interrupt triggered.
8
VERRMIS
VSYNC error interrupt trigger status.
0: No VSYNC error.
1: VSYNC error interrupt triggered.
7
FOMIS
FIFO overflow interrupt trigger status.
Software write 0 to clear. This bit needs to be cleared manually.
0: FIFO has not overflowed.
1: FIFO overflow interrupt triggered.
6
FWMIS
FIFO watermark interrupt status.
This bit is related to the real-time status of the FIFO and can only be cleared by
reading the FIFO.
0: The data length in the FIFO has not reached DVP_CTRL.FWM[2:0].
1: The data length in the FIFO has reached DVP_CTRL.FWM[2:0] and interrupt
triggered.
5
FFMIS
FIFO full interrupt status.
This bit is related to the real-time status of the FIFO and can only be cleared by
reading the FIFO.
0: FIFO is not full.
1: FIFO is full and interrupt triggered.
4
FEMIS
FIFO empty interrupt state.
Software write 0 to clear. This bit needs to be cleared manually.
0: FIFO is not empty
1: FIFO is empty and interrupt triggered.
3
LEMIS
End of line interrupt status.
Software write 0 to clear.
0: Line not ended.
1: Line has ended and interrupt triggered.
2
LSMIS
Line start interrupted state.
Software write 0 to clear.
0: Line not started.
1: Line has started and interrupt triggered.
1
FMEMIS
End of frame interrupt status.
Software write 0 to clear.
0: Frame not ended.
1: Frame has ended and interrupt triggered.
0
FMSMIS
Frame start interrupted state.
Software write 0 to clear.
0: Frame not started.
1: Frame has started and interrupt triggered.