Chapter 3 Installation
UD-series Screw Compressor
3.2 Installation Works
3-4
Figure 3-2 Dimensions of the MYK Flange Joint Part (Compressor)
D
t
φg
φC
N-h
y
10A
56
4.5
37
61
2-M12×P1.75
18
15A
50
4.5
37
68
2-M12×P1.75
18
20A
110
4.5
45
76
2-M12×P1.75
18
□ 25A
91
4.5
52
83
4-M12×P1.75
18
□ 32A
98
4.5
60
95
4-M12×P1.75
18
□ 40A
108
4.5
68
108
4-M12×P1.75
22
□ 50A
120
4.5
84
116
4-M16×P2
24
□ 65CD
144
4.5
85
144
4-M16×P2
27
□ 80A
160
4.5
119
158
4-M20×P2.5
30
□ 100A
192
4.5
144
190
4-M22×P2.5
30
□ 100CD
190
4.5
111
190
4-M22×P2.5
33
125A
270
5
174
230
8-M20×P2.5
27
125CD
274
5
146
230
8-M20×P2.5
25
150A
300
5
199
248
8-M22×P2.5
30
150CD
298
5
176
248
8-M22×P2.5
35
200CD
392
5
234
330
12-M20×P2.5
40
250A
435
5
331
375
12-M24×P3
34
350A
540
5
422
480
16-M24×P3
40