MDP-4806C

Содержание MDP-4806C

Страница 1: ...MDP 4806C ...

Страница 2: ...he Sight Glass built into the lower front area of the Compressor just behind the Regulator check the Oil Level It should be at the halfway mark on the Sight Glass for normal operation If it is necessary to add oil please use any standard air compressor oil available at Home Centers and other major retailers 4 There are two Air Outlet Fittings on the Regulator Air flow for one fitting is operated b...

Страница 3: ...ION 4 4 GENERAL VIEW AND MAIN COMPONETS 4 5 MAIN TECHNICAL PARAMETER 4 6 PREPARATION FOR STARTING 5 7 OPERATION AND ADJUSTMENT 5 8 CAUTIONS 6 6 9 MAINTENANCE 10 TROUBLES AND REMEDIES 7 11 PARTS ILLUSTRATION 8 PARTS LIST 9 12 LIST OF GOODS 9 P 1 WWW PREMIERMUNDO COM ...

Страница 4: ...l ventilated area Do not smoke while spraying Do not spray where sparks or flame are present Keep compressor as far from spray area as possible 2 The solvents Trichloroethane and Methylene Chloride can chemi cally react with aluminum used in paint spray guns paint pumps etc and cause an explosion If you are using these solvents use only stainless steel spray equipment This does not affect your air...

Страница 5: ...ng so voids all warraanties They have been pre set at the factory for the maxinum pressure of this unit CAUTION A POTENTIALL HAZARD THAT MAY CAUSE MODERATE INJURY OR DAMAGE TO EQUIPMENT 1 Drain the mositure from the tank on a daily basis A clean dry tank will help prevent corrosion 2 Pull the pressure relief valve ring daily to ensure that the valve is functioning properly and to clear the valve o...

Страница 6: ...where compressed air is required 1 Main compressor 2 Pressure switch 3 Outlet Valve 4 Regulating Valve 5 Pressure gauge 6 One way Valve 7 Drain cock 8 Wheel 9 Discharge pipe 10 Air tank 11 Fan cover 1 2 3 4 5 6 7 8 9 10 11 Fig 1 Model Power Voltage Frequency Current Rated Speed Displacement Max Working Pressure Tank Capacity Net Weight L W H cm MDP 4806C 2HP 2 5HP 3HP 110V 60Hz 17A 17 5A 3430 RPM ...

Страница 7: ...oped automatically as pressure in creasing to the maximun and restart as pressure decreasing to the minimun The rated pressure has been adjusted when produced Don t change it carelessly As soon as motor switched off the compressed air in the discharge pipe should be released through the release valve under the switch This is the necessary condition for restart or the motor will be damaged The rate...

Страница 8: ... release valve doesn t work as motor stopped find the cause immediately so as not to damage motor 9 Lubricating oil must be clean oil level should be kept in the red circle of leveler 10 Disconnect the plug to cut off power supply and open the outlet valve Table 1 Motor output HP kw 1 0 75 1 5 1 1 2 1 5 2 5 2 100V 110V 120V 2 Wire mm 1 5 1 5 1 5 2 0 Fuse A 16 16 16 20 Single phase 1 Clean crankcas...

Страница 9: ...n 1 Mortor running too slow 2 Air filter choked up 3 Leakage of safety valve 4 Leakage of discharge pipe 5 Sealing gasket damaged 6 Valve plate damaged carbon buildup or stuck 7 Piston ring and cylinder worn of damaged 1 Oil level too high 2 Breath pipe choked up 3 Piston ring and cylinder worn or damaged 1 Keep the level within set range 2 Check and clean 3 Repain or replace 1 Check the line 2 Re...

Страница 10: ...P 8 11 PARTS ILLUSTRATION WWW PREMIERMUNDO COM ...

Страница 11: ...0 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 1 1 1 1 2 2 4 4 4 4 2 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Circlip Locating pin Valve clack Air filter Designation Q ty No Spring Nut M8 Capacitor Fan Fan cover Locating pin Discharge pipe Release pipe Pressure switch Pressure gauge Unilateralism valve Air tank Bolt M8 25 Washer foot Washer 8 Nut...