background image

 

Operating instruction: O003 / 5759 

 

Edition: 04/2019   

 

Reproduction, duplication of this document - even a partial form –  
are subject to our permission. All rights reserved. 

In this data sheet any liability for changes, errors or misprints is excluded.

 

 

Operating Instructions

 

 

Air Cooled Heating Press 

AIR 1200 P 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Müssel Maschinenbau GmbH 

Reichelsweiherstraße 8 

95615 Marktredwitz 

GERMANY 

Tel.: +49 9231 9980-0 

Fax: +49 9231 9980-80 

E-Mail: [email protected] 

Содержание AIR 1200 P

Страница 1: ...ct to our permission All rights reserved In this data sheet any liability for changes errors or misprints is excluded 1 Operating Instructions Air Cooled Heating Press AIR 1200 P M ssel Maschinenbau G...

Страница 2: ...ng tools for conveyor belts and driving belts these devices have been designed according to the latest state of technique and in compliance with this application Please find further information on spl...

Страница 3: ...ng phases 2 5 Mobile devices 2 6 Safety instructions 3 Product description 3 1 Components 3 2 How it works 3 3 Technical data 3 4 Wiring diagram 3 5 Accessories 4 Preparing the product for usage 4 1 T...

Страница 4: ...on O003 5759 Edition 04 2019 Reproduction duplication of this document even a partial form are subject to our permission All rights reserved In this data sheet any liability for changes errors or misp...

Страница 5: ...r changes errors or misprints is excluded 5 1 General information 1 1 Name and address of the manufacturer M ssel Maschinenbau GmbH Reichelsweiherstra e 8 95615 Marktredwitz GERMANY 1 2 Identification...

Страница 6: ...5759 Edition 04 2019 Reproduction duplication of this document even a partial form are subject to our permission All rights reserved In this data sheet any liability for changes errors or misprints is...

Страница 7: ...life of users or third parties or adverse effects to devices and other property The device may only be used in proper technical condition as intended in a safety and hazard con scious manner and obse...

Страница 8: ...articular that all protective and safety oriented devices are in place and fully functional Loosened screws and hose connections must be tightened upon completion of the maintenance and repair work 2...

Страница 9: ...Components Top part Pressure beam Pressure hose Heating plate USB contact Temperature control unit Compressor Compressed air regulator with display Handles Connecting cable of the heating plates Plug...

Страница 10: ...down bar mm 580 Belt length min with hold down bar mm 800 Max splice length mm 90 Heating plates length mm 200 Length mm 200 Length with hold down bar mm 330 Complete width mm 1450 Complete height mm...

Страница 11: ...59 Edition 04 2019 Reproduction duplication of this document even a partial form are subject to our permission All rights reserved In this data sheet any liability for changes errors or misprints is e...

Страница 12: ...f delivery and must be ordered separately Material number Designation 720478 Hold down bar 730088 Handling case 7870174 Separating paper glossy 50 m x 330 mm 7870620 Separating paper matt 50 m x 400 m...

Страница 13: ...ing Make sure that the heating press is firmly locked in lifting In lifting and transporting the device please handle particularly with care During the transport please do not keep staying under the f...

Страница 14: ...ximum of 2 5 bars in exceptional cases The pressing power does not depend on the width of the inserted belt The press is to be closed carefully Fill pressure hose only when the press is firmly closed...

Страница 15: ...ess are blowing cooling air over the heating plates following to the preheating and holding down processes in order to cool down the press The openings for the air input or air output may not be cover...

Страница 16: ...f the same thickness to the left and right next to the ends of the belt refer to the following figure Note Always fold out the areas to be pressed to the full width If the belting material is a narrow...

Страница 17: ...ghtly tighten nut by hand 5 4 Connecting the heating press to the mains 1 Connect the top heating plate with the bottom heating plate so that the latching gets closed 2 Connect the heating press to th...

Страница 18: ...ible air pressure of 2 bar is factory adjusted and may be changed to a max imum of 2 5 bar in exceptional cases During the heating process the pressing power can in crease owing to the thermal expansi...

Страница 19: ...ion Selection of press type No function 4 No function Selection of set up function Selection of press type No function 5 No function Leaving the set up function without changing the parameter or leavi...

Страница 20: ...the following content Press type Belt type AdV Set temperature of the top heating plate F V Set temperature of the bottom heating plate F V Hold down time F V F V F The value of the parameter corresp...

Страница 21: ...item number appears in the first line and the designation of the belt type currently selected ap pears in the second line The 6 digit item number of the desired belt type is to be entered using the ke...

Страница 22: ...60 160 120 400000 Belt4 170 2min 1 170 170 120 500000 Belt5 180 2min 1 180 180 120 600000 Belt6 190 2min 1 190 190 120 Set up of the splice type AdV After selecting the belt type the splice type can b...

Страница 23: ...n on the screen and the user can decide whether the entry will be overwritten or not Belt type Press type Belt type new End This menu point can be switched off with the HPS 2 configuration program or...

Страница 24: ...available at the current se lected belt type When there have already been defined 4 AdVs splice types the foruth type will be defined as the splice AdV 99 and will be overwritten with the modificated...

Страница 25: ...s Key OK starts the set up function The set up menu is ex ited by pressing ESC and the standard display appears The parameter can be changed within the single set up function by using numerical keys K...

Страница 26: ...ature of the pressing process after expiry of the hold down time from which the cooling circuit is shut down if the press type set supports a cooling The valid range is between 0 C and 150 C The value...

Страница 27: ...both heating plates have reached their respective set temper ature Phase 2 The temperature of both heating plates is kept at the set value for the programmed hold down time The remaining pressing time...

Страница 28: ...es can be displayed using key instead of the marquee text in the second line If the programmed cooling temperature falls below the set temperature the cooling output is switched off The end of the pre...

Страница 29: ...n appears in the Error message If multiple errors have been detected these are successively displayed Starting with firmware version 2 03 the following error messages are possible Thermo element 1 The...

Страница 30: ...for changes errors or misprints is excluded 30 5 7 Removing the belt from the heating press 1 Pressure hose is emptied automatically after completion of the heating process 2 Remove the connection cab...

Страница 31: ...otocol memory For using the program please connect the PC with the control unit via USB cable The control unit gets automatically recognized by the PC and by this way any USB driver installation is no...

Страница 32: ...device When using Searching the type list which is stored on a USB stick can be loaded I A it is ques tion here of files dealing with upgrading extension txt or csv The quantity of the belt types avai...

Страница 33: ...using optionally a spreadsheet program according to the figure above The file has to be subsequently saved in csv or txt format with separators Tab The individual columns mean the following Item numb...

Страница 34: ...belt type list as a txt file in any editor Note For this kind the chart is a little bit confusing in vertical direction You can open or create the file with Excel all files and the text converting ass...

Страница 35: ...liability for changes errors or misprints is excluded 35 Configuration It is possible to read different parameter of the control unit with this function The window will be opened with the menu HPS2 C...

Страница 36: ...erung Logging Wert Protokollzeiger Value log indicator Index for the next log entry Protokolleintr ge log entry Number of press processes since the last deletion of the log store Press Zyklen Press cy...

Страница 37: ...37 Date and time With this function you can adjust the internal timer of the control unit An adjustment on the device itself is only possible after switching it and having an invalid internal time re...

Страница 38: ...rs various parameters of every press process into the log store The log store is organized as a ring buffer with a maximum of 2048 entries If the store is filled up the oldest entry will be overwritte...

Страница 39: ...erature value of the top heating plate which results from the splice type of the inserted belt type Delta Soll O value of the nominal value modification in K made by the user of the top heating plate...

Страница 40: ...erature for the current press process Max T Device maximum internal temperature of the control unit during the press process Info Information if the press process has been completely executed or has b...

Страница 41: ...air pressure surface pressure Observe the indications appearing on the display Lubricate with grease setting screw clamping bracket and screws of the hold down bars if necessary Check every twelve mon...

Страница 42: ...he disassembling in individual components can only be effected by competent staff with a good knowledge of machine building Please sort out the device according to the respective materials metal plast...

Отзывы: