(2) After switching off the power supply, mount and install the additional rack.
The connection of the racks and the necessary configuration changes (MIB module) are described
in chapter 12 "Installation". Ensure that the correct CAN bus baud rate and CAN node number
have been selected.
Additional relay modules are to be connected as described under 2.a).
Additional Switching Outputs
The same guidelines (especially those for the MGO module) apply here as to the connection of
additional relays (see chapter 12.10 "Connecting the Relay Outputs"). Instead of the MRO and
MRC TS modules, however, MGT 40 TS modules are required, which are connected via ribbon
cable and an MUT module to the MGO module plugged into the rack (
→
chapter 12 "Installation").
8.3
Connection of Additional Analog Outputs
A maximum of 256 analogue outputs are provided by the SUPREMATouch, corresponding to the
maximum number of sensors that can be connected.
One MAO module makes 8 analogue outputs available. Up to 10 MAO modules can be plugged
in per rack. This is based, however, on the use of at least one additional rack containing the corre-
sponding MAI modules, which make it possible to connect the sensors.
One of the following procedures must be carried out, depending on the extent to which the system
has already been expanded:
1. Not all 8 possible analogue outputs on an existing MAO module have been assigned. The
number of free analogue outputs is equal to the number of new analogue outputs to be
connected.
No additional modules are required. The additional analogue outputs can be connected to the
existing MAT or MAT TS module.
2. All existing MAO modules are assigned, or the number of free analogue outputs is
smaller than the number of new analogue outputs to be connected. A sufficient number of
free slots for additional MAO modules are present in the existing racks.
In this case, additional MAO modules are required in correspondence with the number of new
analogue outputs to be connected.
Additional MAT/MAT TS/MUT modules are also required.
3. All existing MAO modules are full, or the number of free analogue outputs is smaller than
the number of new analogue outputs to be connected. No free slots for additional MAO
modules are available in the existing racks.
In this case, additional MAO modules are required, in correspondence with number of new
analogue outputs to be connected.
Additional MAT/MAT TS/MUT modules are also required.
One or more new racks and the necessary CAN bus connecting cables will also be needed.
WARNING!
Always switch off the power supply when connecting a new rack.
(1) After switching off the power supply, mount and install the additional rack.
The connection of the racks and the necessary configuration changes (MIB module) are described
in the part Installation and Start-Up Manual.
Ensure that the correct CAN bus baud rate and CAN node number have been selected.
Содержание SUPREMATouch MCP 20
Страница 1: ...MSAsafety com Operating Manual SUPREMATouch Fire and Gas Warning Unit Order No 10121863 05...
Страница 8: ...MSAsafety com User Instruction Manual SUPREMATouch Fire and Gas Warning Unit...
Страница 72: ...MSAsafety com Service and Maintenance Guide SUPREMATouch Fire and Gas Warning Unit...
Страница 101: ...8645 Rapperswil Jona Switzerland info ch MSAsafety com www MSAsafety com MSA 2017 All rights reserved...
Страница 232: ...232 Dimensions GB SUPREMATouch 18 Dimensions 18 1 Rack...
Страница 233: ...233 Dimensions GB SUPREMATouch 18 2 Rail mounted Modules MRO8 TS Module MRO16 TS Module...
Страница 235: ...235 Dimensions GB SUPREMATouch MRO20 8 TS Module 1 3 2 69 90...
Страница 236: ...236 Dimensions GB SUPREMATouch MRO20 16 TS Module 2 5 2 64 73 relay dependent 90...
Страница 237: ...237 Dimensions GB SUPREMATouch MRC TS Module MGT40 TS Module...
Страница 238: ...238 Dimensions GB SUPREMATouch MHD TS Module MAT TS Module...
Страница 241: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose...