Update the IO modules (Firmware-
Update with filename “1106iom.fwb”)
1.
Open the path:
E
XTRA
/D
EVICE INFO
2.
Press
F3 = sub.syst
. to open the menu “
S
UB SYSTEMS INFO
”.
3.
Press
F2 = details
, to open the details from the I/O module. Be sure, that the device is
“Mainboard” to update the I/O module
.
4.
The Update will start from the SD-
card, if a firmware with the filename “1106
iom.
fwb” is
at the SD-card.
Or
F3