7.1 Example
7-10
LocalLoop = loopback
RemoteLoop = normal
CrcAutoNego = enable
Bert = enable
CommunicationMode = disable
AlarmStatus = NONE
ErrorSecond = 0
SeriousErrorSecond = 0
BitErrorRate = 1
EthSendPacketNum = 0
EthReceivePacketNum = 2727487
EthReceiveErrorPacketNum = 11721
RemoteDevId = 1
RemoteE1 = 1
LinkStatus = LinkOK
Mro-tek(config-e1/0/1)#
bert
disable
Set Successfully.
Mro-tek(config-e1/0/1)#
no local-e1-loopback
Set Successfully.
Mro-tek(config-e1/0/1)#
end
Mro-tek#
8. Configure remote PINE-8
Mro-tek# config
Configuration mode, one command input per times. End with CTRL-Z.
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
Configuring error auto-shutdown function
Mro-tek(config-remote/0/8)#
err-auto-shutdown
setup successfully!
Mro-tek(config-remote/0/8)#
Enter the Ethernet interface configuration mode.
Mro-tek(config-remote/0/8)#
interface fx-eth
1
Mro-tek(config-fx-eth/0/8/1)#
Enable the flow control function.
Mro-tek(config-fx-eth/0/8/1)#
flow-control
on
setup successfully!
View the information of the Ethernet interface.
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...