The configuration of central site E1 interface of PINE-16M
4-2
The configuration of central site E1 interface of
PINE-16M
Configure the master/slave mode of the clock of E1 interface
Command Description
config
Enter the global configuration mode
interface e1
<1-16>
To Select a specific E1 interface at central site PINE-16M
clock-mode
(master|slave)
To configure the clock mode of a selected E1 interface
show interface
Shows the configuration information of the selected E1
interface
Example:
Mro-tek#
config
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
clock-mode
master
Set Successfully.
Mro-tek(config-e1/0/1)#
Enable or disable the CRC check of the E1 interface
Command Description
config
Enter the global configuration mode
interface e1
<1-16>
To select a specific E1 interface at central site PINE-16M
crc-auto
(enable|disable)
To enable or disable the CRC check of the selected E1 interface
show interface
Shows the configuration information of the selected E1
interface.
If the frame mode of E1 interface is unframed, the enabling of the CRC check will be ineffective.
Example:
Mro-tek#
config
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
crc-auto
enable
NOTE: this config should be invalid if e1 frame-mode is unframed!
Set Successfully.
Mro-tek(config-e1/0/1)#
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...