Configuration of the Ethernet interface of PINE-16M
4-11
Configuration of the Ethernet interface of PINE-
16M
Enabling the Ethernet ports
Under some circumstances, the Ethernet ports have to be shut down for testing. Using the commands
‘
shutdown
’ and ‘
no shutdown
’ user can enable / disable the selected Ethernet port.
By default, all ports are enabled.
Command Description
config
Enter the global configuration mode.
interface eth
<1-2>
To Select a specific Ethernet interface of PINE-16M.
no shutdown
To Enable the selected Ethernet port.
show interface
Shows the configuration information of the Ethernet
interface.
Example:
Mro-tek#
config
Mro-tek(config)#
interface eth
1
Mro-tek(config-eth/0/1)#
no shutdown
setup successfully!
Mro-tek(config-eth/0/1)#
4.5.2 Shut down the ports
Command Description
config
Enter the global configuration mode.
interface eth
<1-2>
To Select a specific Ethernet interface of PINE-16M.
shutdown
To disable the selected Ethernet ports
show interface
Shows the configuration information of the interface.
Example:
Mro-tek#
config
Mro-tek(config)#
interface eth
1
Mro-tek(config-eth/0/1)#
shutdown
Setup successfully!
Mro-tek(config-eth/0/1)#
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...