5.1 Basic configuration of remote inverse multiplexer device
5-2
5.1 Basic configuration of remote inverse
multiplexer device
5.1.1 Configuring fault pass-through function
Command Description
config
Enter the global configuration mode.
remote
0 <1-16>
Enter the remote inverse multiplexer device configuration mode
fault-pass
(enable|disable)
Configure fault pass-through function.
show info
Shows configuration information
This command is only applicable for inverse multiplexer device with electrical interfaces, including PINE-
iE1 and PINE-8.
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
fault-pass
enable
Mro-tek(config-remote/0/8)#
show info
5.1.2 Reset remote device
Command Description
config
Enter the global configuration mode
remote 0
<1-16>
Enter the remote inverse multiplexer device configuration mode.
Reset
Reset the selected remote inverse multiplexer device
Show info
Show the configuration information
This command is applicable for all remote inverse multiplexer devices.
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
reset
Mro-tek(config-remote/0/8)#
show info
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...