5.3 Configuration of E1 interface on remote inverse multiplexer device
5-5
5.3 Configuration of E1 interface on remote
inverse multiplexer device
5.3.1 Configuring clock mode of E1 interface
Command Description
Config
Enter the global configuration mode
remote
0 <1-16>
Enter the remote inverse multiplexer device’s configuration mode.
interface e1
<1-8>
Enter the E1 interface configuration mode of remote inverse multiplexer
device.
clock-mode
(master|slave)
To define a clock mode (Master / Slave).
show interface
Shows the configuration information.
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
interface e1
1
Mro-tek(config-e1/0/8/1)#
clock-mode
master
Mro-tek(config-e1/0/8/1)#
show interface
5.3.2 Configuring CRC options of E1 interface
Command Description
Config
Enter the global configuration mode.
Remote
0 <1-16>
Enter the remote inverse multiplexer device configuration mode.
interface e1
<1-8>
Enter the E1 interface configuration mode of remote inverse multiplexer
device
crc-auto
(enable|disable)
To Enable / Disable E1 CRC mode
show interface
Shows the configuration information
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
interface e1
1
Mro-tek(config-e1/0/8/1)#
crc-auto
enable
Mro-tek(config-e1/0/8/1)#
show interface
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...