7.1 Example
7-7
InMulticastPkts :0
Mro-tek(config-eth/0/2)# end
Mro-tek#
write
Are you sure[Y/N]:y
Please wait..Copy OK: 3109 bytes copied
Save current configuration successfully!
Mro-tek#
5. Configure virtual channel
Mro-tek#
config
Configuration mode, one command input per time. End with CTRL-Z.
Mro-tek(config)#
virtual-channel 1 e1 1-8
Set Successfully.
Mro-tek(config)#
show virtual-channel
virtual-channel informationfor slot 0:
virtual-channel 1 = 1-8
virtual-channel 1 error shutdown disable
Mro-tek(config)#
6. Configuring properties of E1 interface
(only one E1 interface is configured in the example, the
configuration of every E1 interface is the same)
Mro-tek#
config
Configuration mode, one command input per time. End with CTRL-Z.
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
frame-mode
framed
Set Successfully.
Mro-tek(config-e1/0/1)#
clock-mode
master
Set Successfully.
Mro-tek(config-e1/0/1)#
crc-auto
enable
Set Successfully.
Mro-tek(config-e1/0/1)#
show interface
e1 interface information:
slot = 0, portid = 1, ifIndex = 0x20041000
ClockMode = master
FrameMode = framed
Timeslot = 1-31
CrcStatus = disable
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...