7.1 Example
7-9
CrcStatus = disable
LocalLoop = normal
RemoteLoop = loopback
CrcAutoNego = enable
Bert = enable
CommunicationMode = disable
AlarmStatus = NONE
ErrorSecond = 0
SeriousErrorSecond = 0
BitErrorRate = 1
EthSendPacketNum = 0
EthReceivePacketNum = 2727487
EthReceiveErrorPacketNum = 11721
RemoteDevId = 1
RemoteE1 = 1
LinkStatus = LinkOK
Mro-tek(config-e1/0/1)#
Procedures to conduct the BER tester and loopback functions
Mro-tek(config-e1/0/1)#
bert
disable
Set Successfully.
Mro-tek(config-e1/0/1)#
no remote-e1-loopback
Set Successfully.
Mro-tek(config-e1/0/1)#
Enable local loopback.
(Note: before the local loopback of the device is enable, please make sure that the
cables connecting to all E1 ports in the channel the specified E1 port belongs to have been pulled out.)
Mro-tek# config
Configuration mode, one command input per time. End with CTRL-Z.
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
local-e1-loopback
Set Successfully.
Mro-tek(config-e1/0/1)#
bert
enable
Set Successfully.
Mro-tek(config-e1/0/1)#
show interface
e1 interface information:
slot = 0, portid = 1, ifIndex = 0x20041000
ClockMode = master
FrameMode = framed
Timeslot = 1-31
CrcStatus = disable
Содержание PINE-16M
Страница 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Страница 6: ......
Страница 9: ...1 1 Chapter 1 Overview...
Страница 11: ...2 1 Chapter 2 Using Command Lines...
Страница 15: ...3 1 Chapter 3 System Command...
Страница 17: ...4 1 Chapter 4 Configuration at Central Site...
Страница 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Страница 78: ......
Страница 79: ...6 1 Chapter 6 Network Protocol Configuration...
Страница 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...