terminals 1 and 3 of JS1. The input impedance between terminals 1 and 3 is 10K and paralleling
the additional resistor produces an equivalent resistance of 5K. The 2 mA current source will
produce 10.0 V at the external voltage reference input which will produce full scale output
voltage.
The current set point, over voltage trip, and over current trip can be programmed in the same
manner. Referring to the Table 3.1 for terminal identification, use terminal 22 to program the
current set point, terminal 4 to program over voltage trip, and terminal 23 to program over
current trip. The power supply has been calibrated to produce full scale output voltage and
current with 10.0 V inputs at the external reference input terminals. Furthermore, over voltage
and over current trip have been calibrated to trip at 110% full scale output voltage and current
with 10.0 V inputs at the external reference input terminals.
If the applied voltage at any input is greater than 12.50 V, the pgl (program line) LED will light
and the power supply will turn off.
3.5
Voltage and Current Monitoring
Four outputs are provided for monitoring output voltage and output current and for the master
and slave units. As illustrated in figure 3.27, output monitoring voltage, VO2, can be obtained
by monitoring the voltage between terminals terminal 5 of JS1 and terminal 1,2 or 20 of JS1 and
between terminal 16 of JS1 and terminal 1,2 or 20 of JS1, respectively. Output current, IO2, can
be obtained by monitoring the voltage between terminals terminal 24 of JS1 and terminal 1,2 or
20 of JS1 and between terminal 31 of JS1 and terminal 1,2 or 20 of JS1, respectively. Like the
programming inputs, full scale output voltage and current will produce 10.0 V. The output
impedance at these terminals is 100 Ù. The master and slave modules both have a connector
designated as JS1 and work in an identical manner.
Figure 3.27
Monitoring output (a) voltage
and (b) current
53
Содержание DP SERIES II
Страница 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Страница 2: ......
Страница 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Страница 4: ......
Страница 6: ...improper use of the equipment and accessories ii...
Страница 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Страница 29: ...Figure 1 3 DP Series water cooled 10 kW to 30 kW package drawing with D Version front panels 16...
Страница 39: ...Figure 2 3 DPC Series controls and indicators Energizes control circuits without turning on main power 26...
Страница 44: ...Figure 3 2 Set voltage output at memory displayed Figure 3 3 Set current output at memory displayed 31...
Страница 45: ...Figure 3 4 Set over voltage trip at memory displayed Figure 3 5 Set over current trip at memory displayed 32...
Страница 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Страница 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Страница 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Страница 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Страница 53: ...Figure 3 15 Calibration 40...
Страница 56: ...Figure 3 17 Set remote sense Figure 3 18 Set internal control Figure 3 19 Set external control 43...
Страница 57: ...Figure 3 20 Set rotary input Figure 3 21 Set external program input Figure 3 22 Set remote input 44...
Страница 61: ...Figure 3 24 Calibration 48...
Страница 63: ...Figure 3 25 a Local and b remote sensing 50...
Страница 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Страница 111: ...98...
Страница 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Страница 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Страница 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Страница 121: ...Figure 6 1 Block diagram 108...
Страница 128: ...source Figure 8 2 Leadless remote sensing Figure 8 3 IV characteristics for a typical photovoltaic array 115...
Страница 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Страница 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Страница 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...