![MPE DP SERIES II Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/mpe/dp-series-ii/dp-series-ii_operating-and-service-manual_1843048126.webp)
8.0 APPLICATIONS
8.1
General
DP Series power supplies deploy several powerful programming functions that enhance
performance for user specific applications. While the possibilities are endless, a few examples are
presented in this chapter to demonstrate the internal capabilities of the power supply. All of these
examples can be further expanded by operating the unit under computer control.
8.2
Power Waveform Generator
DPD Series power supplies can be programmed to operate as a power waveform generator.
Referring to Section 3.1.1.5, each memory state needs to be programmed for the desired voltage or
current for a specific time period. An example of a power waveform generator and its
corresponding programming values are shown in figure 8.1 and Table 8.1, respectfully. In this
particular example, the voltage set point is changed in 10 second intervals while the current, over
voltage trip, and over current trip are kept constant. To make the power supply repeat the voltage
ramp, a time period of 9998 is entered for step 9. The programming causes the memory state to
jump back to 0 after completing step 8. To start the ramp generator, set the power supply to
memory state 0, press the arm key, and then the start key. Press the stop key to terminate
operation.
Figure 8.1 Sawtooth output voltage
113
Содержание DP SERIES II
Страница 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Страница 2: ......
Страница 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Страница 4: ......
Страница 6: ...improper use of the equipment and accessories ii...
Страница 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Страница 29: ...Figure 1 3 DP Series water cooled 10 kW to 30 kW package drawing with D Version front panels 16...
Страница 39: ...Figure 2 3 DPC Series controls and indicators Energizes control circuits without turning on main power 26...
Страница 44: ...Figure 3 2 Set voltage output at memory displayed Figure 3 3 Set current output at memory displayed 31...
Страница 45: ...Figure 3 4 Set over voltage trip at memory displayed Figure 3 5 Set over current trip at memory displayed 32...
Страница 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Страница 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Страница 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Страница 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Страница 53: ...Figure 3 15 Calibration 40...
Страница 56: ...Figure 3 17 Set remote sense Figure 3 18 Set internal control Figure 3 19 Set external control 43...
Страница 57: ...Figure 3 20 Set rotary input Figure 3 21 Set external program input Figure 3 22 Set remote input 44...
Страница 61: ...Figure 3 24 Calibration 48...
Страница 63: ...Figure 3 25 a Local and b remote sensing 50...
Страница 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Страница 111: ...98...
Страница 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Страница 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Страница 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Страница 121: ...Figure 6 1 Block diagram 108...
Страница 128: ...source Figure 8 2 Leadless remote sensing Figure 8 3 IV characteristics for a typical photovoltaic array 115...
Страница 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Страница 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Страница 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...