2.0 INSTALLATION AND POWER ON CHECK
DP Series power supplies are intended for rack mount installations only and are designed to fit in
standard 19" equipment racks. Additional support, other than that provided by the front panel, is
required. Angle slides or cross beam supports securely fastened to the rack are recommended for
supporting the weight of the power supply. The unit should be horizontally mounted.
Caution: The power supply is too heavy for one person to safely lift and mount.
To avoid injury, ask a co-worker for assistance.
2.1
Cooling
DP Series power supplies are cooled by air or water. Air cooled power supplies are for general
use. Water cooled power supplies are for use in corrosive environments such as plating
applications or in densely packaged system cabinets where heat removal by air cooling presents
a problem. The method of cooling must be specified at time of order.
2.1.1
Air Cooling
Each power supply enclosure is cooled by suitable blowers exhausting warm air to the rear of the
cabinet. Fresh air intake is from the sides of the cabinet allowing two or more DP Series
supplies to be stacked. Equipment racks should be equipped with fans or blowers to remove heat
generated by the power supplies. The manufacturer recommends fresh air intake at the bottom
of the cabinet and exhaust at the top. Fans and blowers should be rated at 800 CFM.
Caution: blocking ventilation will cause the power supply to overheat.
2.1.2
Water Cooling
Water cooling is accomplished with chill plates and an integrated central heat exchanger. The
chill plates provides a thermal conduction path for heat sensitive components and the central heat
exchanger removes heat from air internal to the enclosure. Water cooled DP Series models have
enclosures without vent holes and are basically sealed the unit from the environment. An
internal solenoid valve enables water flow when the chill plate reaches 60°C. Operation of the
solenoid prevents internal condensation.
17
Содержание DP SERIES II
Страница 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Страница 2: ......
Страница 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Страница 4: ......
Страница 6: ...improper use of the equipment and accessories ii...
Страница 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Страница 29: ...Figure 1 3 DP Series water cooled 10 kW to 30 kW package drawing with D Version front panels 16...
Страница 39: ...Figure 2 3 DPC Series controls and indicators Energizes control circuits without turning on main power 26...
Страница 44: ...Figure 3 2 Set voltage output at memory displayed Figure 3 3 Set current output at memory displayed 31...
Страница 45: ...Figure 3 4 Set over voltage trip at memory displayed Figure 3 5 Set over current trip at memory displayed 32...
Страница 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Страница 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Страница 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Страница 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Страница 53: ...Figure 3 15 Calibration 40...
Страница 56: ...Figure 3 17 Set remote sense Figure 3 18 Set internal control Figure 3 19 Set external control 43...
Страница 57: ...Figure 3 20 Set rotary input Figure 3 21 Set external program input Figure 3 22 Set remote input 44...
Страница 61: ...Figure 3 24 Calibration 48...
Страница 63: ...Figure 3 25 a Local and b remote sensing 50...
Страница 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Страница 111: ...98...
Страница 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Страница 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Страница 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Страница 121: ...Figure 6 1 Block diagram 108...
Страница 128: ...source Figure 8 2 Leadless remote sensing Figure 8 3 IV characteristics for a typical photovoltaic array 115...
Страница 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Страница 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Страница 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...