4.3.14.4 MOD:TABL:LOAD
This command moves MODulation:TABLe data from the cache table to the active table and
optionally changes the voltage and current setpoints simultaneously. The first parameter is the
voltage setpoint and the second is the current setpoint.
Command Syntax:
MOD:TABL:LOAD [<NRf>, <NRf>]
Examples:
MOD:TABL:LOAD
MODulation:TABLe:LOAD
MODulation:TABL:LOAD 93.4, 30.3
Query Syntax:
None
Returned Parameters: None
4.3.15 SCPI Data Formats
All data programmed to or returned from the power supply are formatted in ASCII. The data may
be structured as numerical or character string as described in Table 4.3.
Table 4.3 SCPI DATA FORMATS
FORMAT
DESCRIPTON
EXAMPLES
<>
Null, no data.
<NR1>
Digits with an implied decimal point assumed at the right of
the least-significant digit.
-273
0273
<NR2>
Digits with an explicit decimal point.
273.
.0273
<NR3>
Digits with an explicit decimal point and an exponent
2.73E+2
273.0E-2
<NRf>
Extended format that includes <NR1>, <NR2> and <NR3>.
273
-273.0
2.73E2
<NRf+>
Expanded decimal format that includes <NRf>, MIN, and
MAX
273
-273
2.73E2
MIN
MAX
88
Содержание DP SERIES II
Страница 1: ...OPERATING AND SERVICE MANUAL DP SERIES II DC POWER SUPPLIES...
Страница 2: ......
Страница 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 January 6 2010...
Страница 4: ......
Страница 6: ...improper use of the equipment and accessories ii...
Страница 28: ...Figure 1 2 DP Series air cooled 10 kW to 30 kW package drawing with D Version front panel 15...
Страница 29: ...Figure 1 3 DP Series water cooled 10 kW to 30 kW package drawing with D Version front panels 16...
Страница 39: ...Figure 2 3 DPC Series controls and indicators Energizes control circuits without turning on main power 26...
Страница 44: ...Figure 3 2 Set voltage output at memory displayed Figure 3 3 Set current output at memory displayed 31...
Страница 45: ...Figure 3 4 Set over voltage trip at memory displayed Figure 3 5 Set over current trip at memory displayed 32...
Страница 47: ...Figure 3 7 Set remote sense Figure 3 8 Set internal control 34...
Страница 48: ...Figure 3 9 Set external control Figure 3 10 Set rotary input 35...
Страница 49: ...Figure 3 11 Set keypad input Figure 3 12 Set external program input 36...
Страница 50: ...Figure 3 13 Set remote input Figure 3 14 Set external interlock 37...
Страница 53: ...Figure 3 15 Calibration 40...
Страница 56: ...Figure 3 17 Set remote sense Figure 3 18 Set internal control Figure 3 19 Set external control 43...
Страница 57: ...Figure 3 20 Set rotary input Figure 3 21 Set external program input Figure 3 22 Set remote input 44...
Страница 61: ...Figure 3 24 Calibration 48...
Страница 63: ...Figure 3 25 a Local and b remote sensing 50...
Страница 64: ...Figure 3 26 External a resistive b voltage and current programming 51...
Страница 111: ...98...
Страница 113: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 100...
Страница 118: ...Figure 5 7 Register Panel Figure 5 8 Calibration Panel 105...
Страница 119: ...Figure 5 9 Firmware Panel Figure 5 10 Modulation Panel for Version D models only 106...
Страница 121: ...Figure 6 1 Block diagram 108...
Страница 128: ...source Figure 8 2 Leadless remote sensing Figure 8 3 IV characteristics for a typical photovoltaic array 115...
Страница 139: ...Figure B 1 Information Panel Figure B 2 Configure Panel 126...
Страница 140: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 127...
Страница 145: ...Figure D 1 RS485 a 2 wire and b 4 wire connections 132...