9-74 Manual # 42-02-2223
Reference
Digital
Operator
Display
Parameter Description
Unit
Setting
Range
Default
Setting
Factory
Setting
LF.78
Brake drop delay: Time motor will hold full current
and control after direction inputs drop.
sec
0.0-3.00
0.50
0.50 - 0.80
LF.79
Current hold time: Delay in turning off the drive
(Delay to turn OFF the motor current after the
direction is dropped and LF.78 has expired)
sec
0.300 -
3.000
0.300
0.30
Diagnostic Parameters (Read only)
LF.25
Estimated gear ratio
1
LF.80
Software version
LF.81
Software date
MMDD.Y
LF.82
X2A-input state
see tables in
F5 Drive
Manual
LF.83
X2A-output state
LF.86
Operational mode
LF.87
Actual inverter load (100% = rated load)
%
LF.88
Motor command speed
rpm
LF.89
Actual motor speed
rpm
LF.90
Actual elevator speed
ft/m
LF.93
Phase current
A
LF.94
Peak phase current
A
LF.95
Actual DC voltage
V
LF.96
Peak DC Voltage
V
LF.97
Actual output frequency
Hz
O.LF.98 Last error
US - Parameters
US. 1
Password: With different passwords, different
parameter groups can be accessed for advanced
programming.
-
0-9999
-
-
US. 3
Load defaults. Select LoAd and press ENTER to
cause all LF parameters to be reset to drive default
values.
-
LoAd
-
-
US. 4
Load configuration. Select LoAd and press ENTER
to load the configuration selected in US.10.
-
LoAd
-
-
US.10
Select Configuration. User selection of drive mode.
I CLSd = Induction motor (closed loop)
I 9LSS = Induction motor (closed loop) gearless
P CLSd = Synchronous motor (closed loop)
P 9LSS = Synchronous motor (closed loop)gearless
Loaded using parameter US.04
.
-
ICLSd
I 9LSS
P CLSd
P 9LSS
-
*
_________
*
Parameters are motor/machine/job dependent.
**
Recommended but field adjustable.
***
The value is automatically calculated from the motor data or other parameter values.
****
Parameters apply to Drive Software Version 1.71 or greater)
Parameters for Drive Software Version (LF.80 = 1.61 or greater), Software date (LF.81 = 2801.9 or later)
Job #:
Drive Serial #:
Prod. Order #:
Test technician:
Drive Model #:
Date:
Table 9.1 TORQMAX F5 Drive Parameters Quick Reference for iControl AC
Содержание Nidec iControl
Страница 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Страница 15: ......
Страница 23: ...1 8 Manual 42 02 2223 iControl Overview...
Страница 75: ...2 52 Manual 42 02 2223 Construction Mode...
Страница 89: ...3 14 Manual 42 02 2223 Inspection Mode...
Страница 138: ...4 49 Safety Tests iControl AC 4 Figure 4 6 Typical Brake Test Circuit Machine Brake Emergency Brake...
Страница 280: ...6 95 iControl Circuit Board Quick References iControl AC 6 Figure 6 7 Earthquake Board Supporting Information...
Страница 303: ...6 118 Manual 42 02 2223 Troubleshooting...