6-91
iControl Circuit Board Quick References
iControl AC
6
ICE-FML Field Module Logic Board
iField Modules are used to supply power to the brake on iControl AC and DC systems and to the
motor field on iControl with DC drive. The iField Modules used for both purposes are the same,
with the exception of the wiring to terminal J7 on the ICE-FMP, Field Module Power Board.
Figure 6.5 ICE-FML Field Module Logic Board
IFIELD-MODULE Specifications
Inputs: 70 VAC min, 300 VAC max, 1 Phase, 50/60Hz, 42 AMPS Maximum
Outputs: 0 VDC minimum, 265 VDC maximum, 45 AMPS Maximum
OVER-CURRENT PROTECTION REQUIRED ON INPUT
- For loads up to 30A - use Bussman type FNQ or LittleFuse type FLQ
- For loads over 30A - use Ferraz Shawmut type A50QS80-4 or LittleFuse type L50S80
Terminals
1
2
Fan
Fan2
Temp1
Temp2
Terminals on
FMP board
FMO+
FMO-
FMSI
FMCI
FMHC
FMS1
FMS2
FMLD
FMSO
FMX1
FMX2
To SAF
board
TP VI1
TP VI2
Indicators
+15ISO OK
F. BAD
+15 OK
HI TEMP
IGBT FLT
R74
TP 60Hz Ref
To ICE-FMP
board
TP -15
TP GND
TP +15 ISO
TP ISO GND
TP BT1
TP BT2
TP +15
Содержание Nidec iControl
Страница 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Страница 15: ......
Страница 23: ...1 8 Manual 42 02 2223 iControl Overview...
Страница 75: ...2 52 Manual 42 02 2223 Construction Mode...
Страница 89: ...3 14 Manual 42 02 2223 Inspection Mode...
Страница 138: ...4 49 Safety Tests iControl AC 4 Figure 4 6 Typical Brake Test Circuit Machine Brake Emergency Brake...
Страница 280: ...6 95 iControl Circuit Board Quick References iControl AC 6 Figure 6 7 Earthquake Board Supporting Information...
Страница 303: ...6 118 Manual 42 02 2223 Troubleshooting...