6-115
iControl Circuit Board Quick References
iControl AC
6
SC-ION: Serial Control I/O Board
One or more SC-ION boards may be used in an iCentral group controller. The SC-ION board
provides an interface between discrete signal level or relay-oriented field equipment and the
serial communications bus used by iCentral for serial hall calls. Inputs and outputs on the SC-
ION board are assigned unique serial addresses at the factory according to customer require-
ments. Using iView, customers can view the function assigned to each address and may even
assign a different (MCE-supported) function if necessary. Each SC-ION board provides 16 user-
configurable inputs and 16 user-configurable outputs.
I/O Connections
Connect inputs and outputs as shown in your job prints. SC-ION board inputs are always
117VAC. Outputs may be configured (in specific groups) to provide either a path to ground or
current to drive indicator lamps/LEDs.
Output State Selection
The outputs are divided into three groups. Each group shares
a common. The common may be wired to provide a current source or a path to ground. The
groups are:
• Relays 1 — 4
• Relays 5 — 8
• Relays 9 — 16
The commons for the groups are determined by the connections made to board connector J4.
The appropriate connections are determined during the job survey. Each system is configured
before shipment. You need only connect the inputs and outputs as shown on the job prints.
Board Addresses
Each of the 16 inputs and 16 outputs have an address on the system
bus. The addresses are assigned as indicated by the job survey before the system is shipped. The
board may be configured using a serial cable connected from the iView computer to the board.
The configuration screen is available through iView/System/System Configuration/System I/O
- SC-ION board configuration.
Table 6.23 SC-ION Board Inputs and Outputs
Connector
Signal
Connector
Signal
In 1-16:117VAC when active
1: Common
Out 1-16: Determined by common
connection
SHCS: Serial signal, +/-15V bit
stream
SHCC: Serial signal, common
1: Common
SHCS: Serial signal, +/- 15V bit
stream
SHCC: Serial signal, common
- COM 9-16: Connect to select
active output for outputs 9-16.
- COM 5-8: Connect to select
active output for outputs 5-8.
- COM 1-4: Connect to select
active output for outputs 1-4.
Содержание Nidec iControl
Страница 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Страница 15: ......
Страница 23: ...1 8 Manual 42 02 2223 iControl Overview...
Страница 75: ...2 52 Manual 42 02 2223 Construction Mode...
Страница 89: ...3 14 Manual 42 02 2223 Inspection Mode...
Страница 138: ...4 49 Safety Tests iControl AC 4 Figure 4 6 Typical Brake Test Circuit Machine Brake Emergency Brake...
Страница 280: ...6 95 iControl Circuit Board Quick References iControl AC 6 Figure 6 7 Earthquake Board Supporting Information...
Страница 303: ...6 118 Manual 42 02 2223 Troubleshooting...