ɹ˂ʳʽʒʰʕʍʒɁႱࢠ
COOLANT UNIT PROBLEMS
186
ɹ˂ʳʽʒʧʽʡɁͽӦᆬᝓ
Coolant Pump Operation Check
ɹ˂ʳʽʒʧʽʡ˨Ⱦ៶ɜɟȲʁ˂ʵɁᅸԱտȾʧʽʡ
ȟوᢆȪȹȗɞȞᆬᝓȪɑȬǿ
Check if the coolant pump is rotating in the direction of the
arrow on the pump.
2
าᜤ
2
NOTE
1.
ᣡوᢆȪȹȗɞکնɂ፷ɁፖȟᣡᄾȾȽȶȹȗɑȬɁȺǾൡಽ
Ɂʫɮʽʠʶ˂ɵȝɛɆࡾکϫɁൡಽႊໃɁፖɥᆬᝓȪȹȢ
ȳȨȗǿ
1. If the pump is rotating in the opposite direction, wiring is connected
in the reverse phase. Confirm the machine main breaker and
plant-side connections.
2.
ʧʽʡɥሳᤆᢆȨȮȽȗȺȢȳȨȗǿሳᤆᢆȬɞȻʧʽʡȟᆍૺ
ȪɑȬǿ
2. Do not run the pump at idle speed. Idle running will result in
damage to the pump.
ɹ˂ʳʽʒᦀɁᆬᝓ
Coolant Level Check
ɹ˂ʳʽʒʉʽɹɁบᦀȺʉʽɹюȾȕɞɹ˂ʳʽʒᦀɥ
ᆬᝓȪǾɹ˂ʳʽʒᦀȟ˩᪅͇ᣋȾȕɞȻȠɂɹ˂ʳʽʒɥ
ᛃፈȪɑȬǿ
Check the coolant level using the level gage on the coolant
tank. Replenish coolant if the gage indicates that the coolant
level is close to the lower limit.
1
1
“Replenishing Coolant” (page 85)
ɹ˂ʳʽʒʧʽʡᣅɒՠɁᄻᝇɑɝ
Coolant Pump Strainer Clogging
8
ឬ֖
8
WARNING
ൡಽໃɥȪɖȪȹȢȳȨȗǿ
Turn OFF the main power.
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ൡಽໃɥȪɖȬɞǿ
1)
Turn OFF the main power.
2)
ɹ˂ʳʽʒʧʽʡɁ
M6
фᜏሰ͇Ƞʦʵʒ
4
టɥɝ۶
Ȭǿ
2)
Using a hex wrench, remove the four M6 hexagon socket
head cap screws on the coolant pump.
3)
ɹ˂ʳʽʒʧʽʡɥɹ˂ʳʽʒʉʽɹȞɜऀȠҋȬǿ
3)
Pull the coolant pump out of the coolant tank.
Содержание NL1500/500
Страница 8: ......
Страница 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Страница 10: ......
Страница 19: ...FOR SAFE MACHINE OPERATION...
Страница 50: ......
Страница 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Страница 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Страница 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Страница 232: ......
Страница 240: ......
Страница 242: ......