6.3.13. CAN bus alarms
Fault
Cause
Check
CAN_communication_fault
PDO data not received or
received after time-out
Check the wiring and the con
�
guration of the
communication of the drive and/or the CAN master
CAN_rpdo0_time_out
PDO data not received or
received after time-out
CAN_rpdo1_time_out
CAN_rpdo2_time_out
CAN_rpdo3_time_out
CAN_rpdo0_data
PDO data received not
correct
CAN_rpdo1_data
CAN_rpdo2_data
CAN_rpdo3_data
CAN_tpdo0_time_out
PDO data not transmitted or
transmitted after time-out
CAN_tpdo1_time_out
CAN_tpdo2_time_out
CAN_tpdo3_time_out
CAN_tpdo0_data
PDO data not transmitted
CAN_tpdo1_data
CAN_tpdo2_data
CAN_tpdo3_data
CAN_sync_consumer_time_out
Sync not received or
received after time-out
CAN_life_guard_error
Error on life guarding
protocol
Check the con
�
guration
DR2020
MAR2-E-191
77
fi
fi
MAR2-E-191