X10 LN B CAN connector (according to CIA 402 CAN on RJ45 connector)
Pin
Designation
Function
1
Can_H
CAN line positive terminal
2
Can L
CAN line negative terminal
3
0V_Can
CAN line 0 logic
4
Aux_Ps_Fault_neg
Signal (denied) of power supply status
5
Addr_sx_dx
Address for internal communications
6
Ps_out
Power supply command output
7
nc
8
+5V_Can
CAN line power supply (supplied by power supply)
Filter code
AT6013 (power supply M) / AT6014 (power supply L)
Rated voltage
3 x (400/480 V), 50/60 Hz, at 50 °C
Overload
1.5x per 60 s, repeatable every 60 min.
Ambient temperature
From -25 °C to +100 °C, with current reduction starting from 60 °C (1.3%/°C)
Assembly height
1000 m, with current reduction of up to 4000 m (6%/1000 m)
Relative air humidity
15 - 85% (condensate not permitted)
Storage temperature
From -25 °C to +70 °C
IP protection rating
IP20
Acceptance test
Complies with EC
Non-industrial environment -
EN61800-3
complies with radio shielding
Cable length permitted between the drive and motor up to 50 m
Industrial environment -
EN61800-3
complies with radio shielding
Cable length permitted between the drive and motor up to 100 m
Code
Suitable for
power supply Type
Rated
current
[A]
Total
current
loss [W]
Current
on contact
[mA]
Weight
[kg]
Connection [mm
2
]
AT6013
L50
A 1
55
26
33.4
1.8
13 mm
2
�
ex.
PE M6 bolt
AT6014
L150
B 1
130
50
39
2.6
Up to 50 mm
2
PE M10 bolt
DR2020
MAR2-E-191
19
2.2.4 Filters
If the motor power cables are shorter than 50 m, an EMC filter (code AT6013/AT6014 or equivalent can be positioned between
the network and the drive.
If cables are no longer than 50 m, we recommend contacting Moog-Casella's Application Dept.
If the application requires a direct current less than the maximun than can be managed by the power supply, filters with lower rated
curent values may be used.
Contact the Application Service for ratings and a selection of alternative models to those described above.