5.7. Oscilloscope function and lo��les (“.UCX”)
It is possible to record and view numerous variables within the drive.
From the
Navigation area
, select “
Digital oscilloscope
”.
5.7.1. Con�gure recording
Select the “
Channels
” tab. For each channel, choose the variable you want to view from the drop-down menu.
The number of variables that can be accessed depends on the user access mode (“Advanced” or “Normal”).
To change the access mode, select “Options/modes” from the toolbar and continue with your choice.
A maximum of four tracks can be viewed..
Set the duration of the recording in msec (“
Recording time
”) and the “
Sampling frequency
” in Hz.
It is possible to trigger viewing (and recording) on a speci
�
c event by choosing “
Enabled
” from the “
Trigger
”
�
eld (choosing
“
Continuous
” will automatically provide repeated views of the same event).
To con
�
gure the trigger: Choose the trigger variable from those which appear in the drop-down menu in the “
Variable
”
�
eld.
Next, choose the front (“Ascent”/“Descent” in the “
Front
”
�
eld) and the level of activation of the trigger (numeric value, in the
“
Level
��
eld).
The setting of the “
Pre Trigger
” allows users to view up to 512 bytes before the signal is triggered.
5.7.2. Launch recording
Select the “
Activation
” tab.
From the “
Select output
” field, choose one of the three options from the drop-down menu:
• See in GUI: The sizes are only viewed and not recorded
• Local save: The sizes are viewed and saved on the PC in the directory indicated in the “
Output folder
” field
Launch recording by pressing the “
Start
” button and stop by pressing the “
Stop
” button.
MAR2-E-191
67
g fi
fi
fi
fi
fi
fi
fi
fi