11
- 7
11.1 Troubleshooting
11
TROUBLESHOOTING
(Continued on next page)
Table11.3 Troubleshooting for other symptoms (Continued)
No.
Symptom
Check point
Corrective action
Reference
5
The diagnostic counter
has counted up.
Master
Received exception error
count
Check the exception code returned from
the slave by the Error log (address: 0CFE
H
to 0DFF
H
) in the buffer memory, and
examine the slave to solve the problem.
No-response count
Refer to the corrective actions for the
response monitoring timer timeout error
(error code: 7378
H
to 7379
H
).
Received NAK count
Examine the slave that returned the error,
and solve the problem.
-
Received busy count
Message discard count
• When there is another master on the
same network, disconnect the master.
• When a response is returned after
occurrence of the response monitoring
timer timeout error, refer to the
corrective actions for the error (error
code: 7378
H
to 7379
H
).
• When any of the other stations has sent
a message without receiving a request,
examine the station.
Slave
Message discard count
There is no problem as messages
addressed to other stations are discarded.
Exception error count
Check the Error log (address: 0CFE
H
to
0DFF
H
) in the buffer memory and take
corrective actions for the error code.