10
DEDICATED INSTRUCTIONS
10.3 Z(P).MBREQ
10
- 16
9
P
R
OGRAM
M
ING
10
D
E
DICA
TED
INSTRUC
TI
ONS
11
TR
O
U
BLE
S
HOOTING
A
P
P
E
NDICE
S
INDE
X
(2) Control data
* 1 The setting side is as described below.
User : Data are set by the user before dedicated instruction execution.
System: The programmable controller CPU stores the result of dedicated instruction execution.
* 2 For function codes that can be broadcast, refer to the following:
* 3 When specifying a value of 32768 (8000
H
) or more in a sequence program, set the value in
hexadecimal.
Table10.10 Control data of the MBREQ instruction
Device
Item
Setting data
Setting
range
Setting
side
*1
(S1)+0
-
Specify 0.
0
User
(S1)+1
Completion
status
The status of the instruction completion is stored.
0 : Normal completion
Other than 0: Error completion (error code) (
-
System
(S1)+2
-
Specify 0.
0
User
(S1)+3
Channel
Specify the target channel.
1: RS-232
2: RS-422/485
1, 2
User
(S1)+4
-
Specify 0.
0
User
(S1)+5
Target station
No.
Specify the station number of the target slave.
0 : Broadcast
*2
1 to 247: Slave station No.
0 to 247
User
(S1)+6
-
Specify 0.
0
User
(S1)+7
Response
monitoring
timer value/
Broadcast
delay value
[Response monitoring timer value (Target station No. is 1 to 247)]
Specify the time for monitoring a response from the target device (slave).
(Unit: 10ms)
0 : 30 seconds
2 to 65535: Set value (Response monitoring timer value = set value x 10ms)
[Broadcast delay value (Target station No. is 0)]
Specify the wait time after broadcast transmission. (Unit: 10ms)
0 : 400ms
2 to 65535: Set value (Broadcast delay value = set value x 10ms)
For details on the Response monitoring timer value/Broadcast delay value,
refer to the following.
0
2 to 65535
*3
User
Содержание QJ71MB91
Страница 1: ......
Страница 2: ......
Страница 366: ...App 14 Appendix 4 External Dimensions APPENDICES Memo ...
Страница 371: ......
Страница 372: ......