1 - 42
1 OVERVIEW
(2) Parameters common throughout the Multiple CPU system
In the Motion CPU, at the initial setting the parameters in the table below are
verified against the parameters in the PLC CPU of CPU No.1. Unmatched
parameters generate a PARAMETER ERROR (error code: 3012), so the
parameters show below must be set identically between Motion CPUs and the
PLC CPU of CPU No.1. (If the system settings are changed in a Motion CPU, it is
necessary to reset. Therefore, the parameters are checked only at the initial
setting.)
PLC CPUs can use the parameters of the other CPUs via "Multiple CPU
parameter utilization" in GX Developer. Since Motion CPUs do not have this
function, however, the common parameters must be set for each Motion CPU.
Type of parameter
Name in Motion CPU
Name in PLC CPU
Verification item
Remark
Number of Multiple CPUs
Number of CPU modules
Operation mode
Operation mode when a CPU
stop error occurred
Multiple CPU settings
Automatic refresh setting
Number of automatic refresh
points
Motion slot settings
Control CPU Control CPU No.
• Only the module numbers
set in System Settings on
the Motion CPU side are
verified.
Total number of bases
Base No.
Base settings
I/O assignment
Basic
settings
Base
Number of base slots
• Not verified if base settings
are omitted on the PLC CPU
side.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...