8 - 6
8 AUXILIARY AND APPLIED FUNCTIONS
(3) ON region setting
(a) The data range which makes the output device turn ON/OFF toward the
watch data.
(b) The following devices can be used as the ON Value and OFF Value of the
data range.
The data type of device/constant to be set is the same as the type of watch
data.
Item
Device No. setting range
Data register
D0 to D8191
Link register
W0 to W1FFF
Motion register
#0 to #8191
Constant Hn/Kn
(4) Output enable/disable bit
`(a) Set the status of output enable/disable bit when the limit switch output is
forbidden during operation.
1) The following control is exercised.
Output enable/disable bit status
Control description
Without setting (always enable)
ON (enable)
Limit switch output is turned ON/OFF based on the
ON region setting (ON Value, OFF Value).
With setting
OFF (disable)
Limit switch output is turned OFF.
(b) Usable devices
Item
Device No. setting range
Input relay
(Note-1)
X0
to
X1FFF
Output relay
(Note-2)
Y0 to Y1FFF
Internal relay
M0 to M8191
Latch relay
L0 to L8191
Link relay
B0 to B1FFF
Annunciator
F0 to F2047
Special relay
M9000 to M9255
(Note-1) : The real input range(PX) is included.
(Note-2) : The real input range(PY) is included.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...