![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 246](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836246.webp)
6 - 17
6 PARAMETERS FOR POSITIONING CONTROL
6.3.3 Speed control gain 1, 2
(1) Speed control gain 1
(a) For speed control mode
Normally, it is not necessary to change.
(b) For position control mode
Set to increase the follow-up for commands.
(2) Speed control gain 2
(a) This gain is set when vibration occurs, for example in low-rigidity machines
or machines with a large backlash.
If this gain is increased, responsiveness is improved but vibration (abnormal
motor noise) becomes more likely.
(b) A guide to setting position gain 2 is shown in Table 6.5 below.
Table 6.5 Guide to speed control gain 2 setting
Load inertia ratio
(
GD
L2
/
GD
M2
)
1
3
5
10
20
30 or more
Remarks
Setting value [ms]
800
1000
1500
2000
2000
2000
Setting range of 1 to
9999 can be set.
(Valid range: 20 to 5000)
POINTS
(1) When the setting for speed control gain 1 is too high, the overshoot becomes
greater and vibration (abnormal motor noise) occurs on stopping.
(2) The speed control gain 1 setting can be checked using a peripheral device.
(Refer to the help of each software for the monitoring method of the speed
control gain1 using a peripheral device.)
6.3.4 Speed integral compensation
(1) This parameter is used to increase frequency response in speed control and
improve transient characteristics.
(2) If the overshoot in acceleration/deceleration cannot be made smaller by adjusting
speed loop gain or speed control gain, increasing the setting for the speed integral
compensation value will be effective.
(3) A guide to setting the speed integral compensation is shown in Table 6.6 below.
Table 6.6 Guide to speed integral compensation setting
Load inertia ratio
(
GD
L2
/
GD
M2
)
1
3
5
10
20
30 or more
Remarks
Setting value [ms]
20
30
40
60
100
200
Setting range of 1 to 9999
can be set.
(Valid range: 1 to 1000)
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...