![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 599](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836599.webp)
APP - 38
APPENDICES
Table 2.13 Servo error (2000 to 2799) list (Continued)
Error cause
Error
code
Name Description
Error check
Error
processing
Corrective action
2196
Home position
setting error
warning
• After a home position return command,
the droop pulses did not become within
the in-position range.
Operation
continues
• Execute the home position
return again.
Parameter error
• The servo parameter value is outside the
setting range. (Any unauthorized
parameter is ignored and the value
before setting is held.)
2301
Amplifier
setting
2302
Regenerative
resistor
2303
Motor
type
2304
Motor
capacity
2305
Motor
speed
2306 Number of feedback pulses
2307 Rotation direction setting
2308 Automatic tuning setting
2309
Servo
response
setting
2310 Torque limit (forward)
2311 Torque limit (reverse)
2312 Load inertia ratio
2313 Position control gain 1
2314 Speed control gain 1
2315 Position control gain 2
2316 Speed control gain 2
2301
2317 Speed integral compensation
to
2318 Notch filter selection
2336
2319 Feed forward gain
2320
In-position
range
2321
Electromagnetic brake sequence
2322
Monitor output mode selection
2323 Optional function 1
2324
Optional
function
2
2325
Optional
function
3
2326
Optional
function
4
2327 Monitor output 1 offset
2328 Monitor output 2 offset
2329 Pre-alarm data selection
2330
Zero
speed
2331 Error excessive alarm level
2332
Optional
function
5
2333
Optional
function
6
2334 PI-PID control switch-over
position droop
2335
Torque limit compensation factor
2336
Speed differential compensation
(Real speed differential
compensation)
Parameter
error
(Servo
amplifier)
Any time during
operation
Operation
continues
• Check the setting ranges of the
servo parameters.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...