![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 253](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836253.webp)
6 - 24
6 PARAMETERS FOR POSITIONING CONTROL
6.3.23 Servo parameters of vector inverter (FR-V500)
The servo parameters to be set are shown in Tables 6.7.
Refer to the "Vector inverter Instruction Manual" for details of the vector inverter.
Instruction Manual list is shown below.
Vector inverter type
Instruction manual name
FR-V500
FR-V500 Instruction Manual [Basic] (IB-0600064)
FR-V500 Instruction Manual [Detailed] (IB-0600131E)
FR-V5NS Instruction Manual (IB-0600106E)
Table 6.7 Vector inverter parameter list
Initial value
No.
Setting
details
Inverter
parameter
No.
Japan
North
America
Europe
Setting range
Units
1 Maximum speed
1
1500
1800
1500
0 to 3600
1r/min
2 Electronic thermal O/L relay
9
0.00
0.00 to 500.00
0.01A
3 Regenerative function selection
30
0
0 to 2
1
4 Special regenerative brake duty
70
0.0
0.0 to 30.0
0.1%
5 Applied motor
71
30
0
0
0, 3 to 8, 10, 13 to 18, 20, 23, 24, 30
1
6 Motor
capacity
(Note-3)
80
Inverter capacity
0.75 to 55.00
0.01kW
7 Number of motor poles
81
4
2, 4, 6, 8
1
8 Online auto turning selection
95
0
0, 1, 2
1
9 Torque restriction level
22
150.0
0.0 to 400.0
0.1%
10 Torque restriction level (regeneration)
812
11 Torque restriction level (3 quadrant)
813
12 Torque restriction level (4 quadrant)
814
Restriction by the value of Pr.9
Restriction by the value of "0.0 to 400.0"
or Pr.9
0.1%
13 Easy gain tuning response level setting
818
2
1 to 15
1
14 Easy gain tuning selection
819
0
0, 1, 2
1
15 Number of encoder pulses
851
2048
1024
1024
0 to 4096
1
16 Encoder rotation direction
852
1
0, 1
1
B
as
ic par
ame
te
rs
17 Thermal relay protector input
876
1
0
0
0, 1
1
18 Position loop gain
422
25
0 to 150
1sec-1
19 Position feed forward gain
423
0
0 to 100
1%
20 In-position width
426
0.01
0.0001 to 3.2767
0.0001mm
21 Excessive level error
427
40
0 to 400
1KPLS
22 Speed control P gain 1
820
60
0 to 1000
1%
23 Speed control integral time/
821
0.333
0.000 to 20.000
0.001s
24 Model speed control gain
828
60
0 to 1000
1%
25 Notch filter frequency
862
0
0 to 31
1
26 Notch filter depth
863
0
0 to 3
1
27
Speed feed forward control/model
adaptive speed control selection
877 0
0
to
2
1
28 Speed feed forward filter
878
0.00
0.00 to 1.00
0.01s
29 Speed feed forward torque restriction
879
150.000
0.000 to 400.000
0.001%
30 Load inertia ratio
880
7.0
0.0, 1.0 to 200.0
0.1
A
dj
ust
m
ent
p
ar
am
et
er
s
31 Speed feed forward gain
881
0
0 to 1000
1%
32 DA1 terminal function selection
54
1
1 to 3, 5 to 12, 17, 18, 21, 32 to 34, 36
1
33 Speed monitoring reference
55
1500
1800
1500
0 to 3600
1r/min
34 Current monitoring reference
56
0.00
0.00 to 500.00
0.01A
35 DA2 terminal function selection
158
1
1 to 3, 5 to 12, 17, 18, 21, 32 to 34, 36
1
36 Overspeed detection level
374
3450
4200
3450
0 to 4200
1r/min
37 Torque characteristic selection
801
1
0, 1
1
38
Constant output region torque
characteristic selection
803 0
0,
1 1
E
xpa
ns
ion
pa
ra
me
ter
s
39 Torque monitoring reference
866
150.0
0.0 to 400.0
0.1%
(Note-1) : The above parameters become valid immediately after change.
(Note-2) : Set the vector inverter parameters except the above parameters using an operation panel or parameter module.
(Note-3) : Usable motor capacity is equivalent to vector inverter capacity, or under 1 rank.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...