![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 249](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836249.webp)
6 - 20
6 PARAMETERS FOR POSITIONING CONTROL
6.3.11 Electromagnetic brake sequence
This parameter sets the delay time between the electromagnetic brake operation and
base disconnection.
6.3.12 Monitor output mode
This parameter is set to output the operation status of the servo amplifier in real time as
analog data.
The operation status can be checked by analog output.
There are two monitor items to be set according with the servo amplifier to be used.
6.3.13 Optional function 1
(1) Carrier frequency selection
When low noise is set, the amount of electromagnetic noise of audible
frequencies emitted from the motor can be reduced.
(2) Serial encoder cable selection
Set the type of serial encoder cable to be used.
0
0
Carrier frequency selection
3 : 9kHz (low-noise)
0 : 2.25kHz (non low-noise)
Encoder type
1 : 4-wire type
0 : 2-wire type
POINT
Optional function 1 (carrier frequency selection)
When low-noise is set, the continuous output capacity of the motor is reduced.
(3) External forced stop selection (MR-J2S- B/MR-J2- B only)
The external forced stop signal (EM1) can be made invalid.
0: External forced stop signal is valid.
1: External forced stop signal is invalid (automatically turned on internally).
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...