1 - 40
1 OVERVIEW
1.5 System Settings
1.5.1 System data settings
The table below lists the system data items to be set.
Item Setting
range
Initial
value
Remark
CPU base
2/3/5/8/10/12 slots
CPU base : 2 slots
Base setting
Extension base
None/2/3/5/8/10/12 slots
None
Set the number of slots in the CPU base
or extension base.
Number of Multiple
CPUs
2/3/4 modules
2 modules
Set the total number of Multiple CPUs
including PLC CPU(s).
Automatic refresh
setting
Up to 2k words of devices
(D/W/#/M/Y/B) can be set
per CPU for settings 1 to 4.
None
Set the automatic refresh between CPUs
using Multiple CPU shared memory.
Multiple CPU
setting
Error operation mode at
the stop of CPU
Stop/do not stop all CPUs
upon an error in CPU Nos.
1/2/3/4.
(The setting range varies
depending on the number of
Multiple CPUs installed.)
Stop all CPUs upon
error in CPU Nos.
1/2/3/4
Set whether or not to stop the entire
system when a CPU stop error occurs in
each CPU.
Module arrangement
Within the CPU base and
extension base slots
None
Install the modules controlled by the self
CPU in the CPU base and/or extension
base(s).
Common
system
parameters
Motion slot
setting
Individual module
Varies depending on the
module.
Varies depending on
the module.
Set detailed items for each module
controlled by the self CPU.
Operation cycle setting
0.8 ms/1.7 ms/3.5 ms/7.1ms
/14.2ms/Auto
Auto
Set the operation cycle of motion control.
Operation at
STOP to RUN
M2000 is turned on with
switch (STOP to RUN).
/M2000 turns ON by
switching (STOP to RUN) +
1 set in setting register.
M2000 is turned on
with switch (STOP to
RUN).
Set the condition in which the PLC ready
flag (M2000) turns on.
Forced stop
(Note)
None/X (PX) (0 to 1FFF)/
M (0 to 8191)
None
Set the bit device used for forced stop.
Basic system
setting
Latch range
M (0 to 8191)/B (0 to 1FFF)/
F (0 to 2047)/D (0 to 8191)/
W (0 to 1FFF)
None
Set the latch range of device memory.
Self CPU installation position setting
Set self CPU/another CPU/
CPU (empty) for slots 0/1/2.
(The setting range varies
depending on the number of
Multiple CPUs installed.)
None
(When two CPUs are
installed, slot 0 is
fixed as the self
CPU.)
Set the installation position of the self
CPU in the CPU base.
Servo amplifier/motor setting
Q173CPU(N):
Up to 2 systems, 32 axes
Q172CPU(N):
Up to 1 system, 8 axes
None
Set the model name, axis No. and other
details for the servo amplifiers and
servomotors.
High-speed read setting
One Q173PX module and
one input module.
None
Set the high-speed read data. Refer to "
8.12 High-Speed Reading of Specified
Data " for the high-speed read function.
Individual
parameters
Battery setting
External battery unused/
External battery used
External battery
unused.
Set whether or not to use an external
battery. If the power supply is down for
one month or longer, data must be
backed up with an external battery. Refer
to "Q173CPU(N)/Q172CPU(N) User’s
Manual" for external battery.
(Note) : The forced stop can also be executed by the forced stop terminal of the servo amplifier besides the forced stop input setting.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...