![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 606](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836606.webp)
APP - 45
APPENDICES
APPENDIX 2.5 PC link communication errors
Table 2.14 PC link communication error codes list
Error codes stored
in D9196
Error description
Corrective action
01
• A receiving packet for PC link
communication does not
arrive.
• The arrival timing of the
receiving packet is too late.
• Check whether the power of PC has
been turned on.
• Check the connection of the
communication cable.
• Check the communication cable for
wire breakage.
• Check whether the A
0BD-PCF/
A30CD-PCF has been installed
correctly.
02
• A receiving packet CRC code
is not right.
• Check whether there is a noise
source near the PC.
• Check the connection of the
communication cable.
• Check the communication cable for
wire breakage.
03
• A receiving packet data ID is
not right.
• Check whether the A
0BD-PCF/
A30CD-PCF has been installed
correctly.
• Replace the A
0BD-PCF/A30CD-
PCF.
04
• The number of received
frames is not right.
• Check whether there is a noise
source near the PC
• Check the connection of the
communication cable.
• Check the communication cable for
wire breakage.
05
• A PC communication task
does not start.
• Start the communication task for PC
side.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...