![Mitsubishi Electric Q172CPU Скачать руководство пользователя страница 438](http://html.mh-extra.com/html/mitsubishi-electric/q172cpu/q172cpu_programming-manual_1811836438.webp)
7 - 177
7 MOTION PROGRAMS FOR POSITIONING CONTROL
An operation error will occur if :
(a) Number of words (n) to be written is outside the range of 1 to 256.
(b) The shared CPU memory address (D) of self CPU of the writing destination
device is outside the range (800H to FFFH) of the shared CPU memory
address.
(c) The shared CPU memory address (D) of self CPU of the writing destination
number of words (n) to be written is outside the range (800H to
FFFH) of the shared CPU memory address.
(d) First device No. (S) which writing data are number of words (n) to
be written is outside the device range.
(e) MULTW instruction was executed again before MULTW instruction is
executed and complete bit device is turned on.
[Program Example]
2-word from D0 is written in the shared CPU memory to since A00H.
RST #M0 ;
MULTW HA00 #D0 2 #M0 ;
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...