5 - 84
5 POSITIONING DEDICATED SIGNALS
(2) Motion CPU WDT error cause (D9184) ………........ Monitor device
This register is used as judgement of the error contents in the Motion CPU.
Error code
Error cause
Operation when error
occurs
Action to take
1
S/W falut 1
2
Operation cycle time over
• Reset with the reset key.
• If the error reoccurs after resetting,
change the operation cycle into a large
value in the system setting.
3
Q bus WDT error
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
4 WDT
error
30
Information processor H/W error
• Reset with the reset key.
• If the error reoccurs after resetting,
explain the error symptom and get
advice from our sales representatives.
201 to 215
Q bus H/W fault
201
Error contents
01 : Q bus error 1
02 : Q bus error 2
04 : Q bus error 4
08 : Q bus error 8
Error code = Total of the error co 200
250 to 253
Servo amplifier (MR-
B) interface H/W fault
250
Faulty SSCNET No.
0 : SSCNET 1
1 : SSCENT 2
2 : SSCNET 3
3 : SSCNET 4
Error code = Total of the faulty SSCNET No. + 250
• Reset with the reset key.
• If the error reoccurs after resetting, the
relevant module or the relevant slot
(base unit) is probably faulty: replace
the module/base unit.
300
S/W fault3
• Reset with the reset key.
8 or more points of CPSTART instruction were used
to start programs in excess of simultaneously
startable program.
Number of simultaneous startable programs
14
301
• Reset with the reset key.
• Use 8 or more points of CPSTART
instruction to start programs within the
number of simultaneously startable
programs.
302
During ROM operation, the system setting data,
programs and parameters written to internal FLASH
ROM are fault.
All axes stop immediately,
after which operation
cannot be started.
• Write the system setting data,
programs and parameters to the
internal FLASH ROM.
Содержание Q172CPU
Страница 1: ...Q173CPU N Q172CPU N Motion Controller SV43 Programming Manual Q172CPU Q173CPU Q172CPUN Q173CPUN ...
Страница 229: ...5 88 5 POSITIONING DEDICATED SIGNALS MEMO ...
Страница 447: ...7 186 7 MOTION PROGRAMS FOR POSITIONING CONTROL MEMO ...
Страница 535: ...8 88 8 AUXILIARY AND APPLIED FUNCTIONS MEMO ...
Страница 557: ...11 10 11 COMMUNICATIONS VIA NETWORK MEMO ...
Страница 559: ...12 2 12 MONITOR FUNCTION OF THE MAIN CYCLE MEMO ...